How Does The AB 9000 Automatic Balancer Work

The balancer installation typically consists of a controller, a vibration sensor, a balancer ring fitted to the shaft or spindle and a fixed stator assembly. The system monitors the vibration at the shaft rotational frequency (imbalance), once an increase in imbalance vibration is detected which breaches pre defined alarm limits the controller pulses power to the balancer ring through the stator which commands the balancer rings to move to counter imbalance forces of the rotating shaft assembly. Once the vibration has reduced below a lower pre defined vibration limit the system ceases the balancer movements and continues to monitor for changes.